Colocation/Full Rack

Full Rack

A complete cabinet for your platform, with dual 32A feeds, metered and switched PDUs, and a water-cooled rear-door heat exchanger for efficient, high-density cooling.

42U, lockable Dual 32A feeds (A+B) Metered & switched PDUs From £795.00/mo
What's included

Everything in your full rack

Best for: A complete production platform, or several clusters.

42U, lockable

A whole cabinet, locked and yours.

Dual 32A feeds

16 A (3.68 kW) committed included, up to 32 A (7.36 kW) on A+B 32A feeds.

Metered & switched PDUs

Live per-outlet power and remote power-cycling from the client area.

Water-cooled rear door

A rear-door heat exchanger removes heat at the rack: efficient, and ready for high density.

Cross-connects available

To carriers in our meet-me room, our transit, or L2 across our UK ring.

ISO 27001 security

Audited access control, CCTV and visitor logging across the site.

Green power

Our own 200kW solar farm plus renewable grid supply.

Remote hands

Reboots, drive swaps, tape rotations, receiving and racking by our on-site engineers.

On AS48070

Blended transit and our UK ring to London and Manchester, a cross-connect away.

The space

What your space looks like

The whole 42U cabinet is yours, locked, with A+B PDUs at the rear.

151015202530354042Your rack · 42U (locked)42U≈ 1867 mm42U cabinet · front view
Front view of the cabinet.
Cold aisleHot aisleA+B PDUsWater-cooled rear doorFront1200 mm deep42U≈ 1867 mm
Side view: front-to-back airflow from the cold aisle, with a water-cooled rear door removing heat at the back of the rack.
Space42U lockable cabinet
Cabinet42U, 1200 mm deep (width to confirm)
Power16 A (3.68 kW) committed included, up to 32 A (7.36 kW)
FeedsDual 32A (A+B)
PDUMetered & switched
CoolingWater-cooled rear-door heat exchanger
AccessBy appointment (to confirm)
Racks with water-cooled rear-door heat exchangers in Hall B

The data centre

Our own Tier 3, ISO 27001 certified facility in Peterborough: a 20-rack traditional hall (Hall A) and a 40-rack hall with rear-door heat exchangers (Hall B), 1MW of IT load, and a 200kW solar farm on site.

Rack widths, access arrangements and anything marked “to confirm” are placeholders. All racks are 1200 mm deep with A+B power as standard.

Price it

Build your full rack

Choose power, connectivity and support. The price updates as you go, then continue to the client area to order and pay.

1 Power

Dual 32A feeds (A+B). Extra committed power is £21.85 per amp (£95.00 per kW) per month; energy above your commit is metered at £0.30/kWh.

2 Connectivity

Public IPv4 (IPv6 included)
Cross-connects (£45.00/mo + £150.00 setup each)0

3 Remote hands

4 Contract term

Setup fees are waived on 36-month terms.

Your full rack

Full Rack£795.00
Transit: 100 Mbps commit£150.00
IPv4 /29 (5 usable) + IPv6£6.00
12 months discount−£47.55
Monthly, ex VAT£903.45
One-off setup£250.00
Continue to order

You'll review everything and pay in the client area. Prices exclude VAT.

Mockup: prices are placeholders.

FAQ

Common questions

How much power can a full rack take?

Up to 32 A (7.36 kW) on dual 32A feeds. Full racks have a water-cooled rear-door heat exchanger, which removes heat at the back of the rack and copes well with high-density kit.

How is power billed?

Your committed power is included in the monthly price. If you use more energy than your commit allows over the month, the extra is metered per kWh.

Can you rack the equipment for us?

Yes. Ship it to us and our engineers will receive, rack and cable it, with photos in your ticket.

Want to see it first?

Come and look round the hangar, or talk through your power and cooling with an engineer.

Book a site visit